MINIMUM
PLAN SUBMITTAL REQUIREMENTS
- ALL
PROJECTS:
Project name, address, and legal description.
Scale. Drawing title, number, and page.
Drawing and revisions dates. Name address,
and phone of party responsible for drawing.
Owner name, address, and phone number.
Applicant name (must be individual), address,
and phone number. Description of existing
and proposed use.
- DESCRIPTION
OF WORK: Summary description of the
proposed work. May include description
of construction, scope, and extent of
work.
- SITE
PLAN: Dimensions from each property
line and other structures. Existing and
proposed building dimensions. Parking
layout, site topography, structure elevations,
utility locations, setbacks, landscaping
and screening, and use description.
- FOUNDATION
PLANS: Dimensional location of all
footings and foundations. Dimensions of
each footing type and foundation type.
Footing and foundations material specifications
Reinforcing type, size, and spacing. Soil
bearing requirements.
- FLOOR
PLANS: Building dimensions. Location
of project within building. Dimensions
of each space and / or room. Use description
of each room. Use description of adjacent
spaces. Dimensioned location of all partitions,
exits, door openings, corridor locations,
stair locations, ramp locations, and firewall
locations. Exit route within building
to exterior. Sanitation facilities, including
toilet room details. Seating and fixture
layouts. Guardrail and handrail locations
and details.
- BUILDING
ELEVATIONS: Floor to floor dimensions.
Roof height dimensions. Exterior finish
materials. Exterior wall opening type
and locations. Roof opening location.
Parapet locations. Exterior appendages,
and projections.
- ROOF
PLAN: Roof slope. Roof drain type
and location. Roof covering type, material,
and classification. Roof ventilation size
and locations. Roof opening location.
Parapet locations. Penthouse dimensions.
Location of all mechanical equipment and
enclosures
- STRUCTURAL
PLANS: Dimensions and layout of each
level. Size, spacing, type, and location
of all floor framing members and roof
framing members. Size, type, spacing,
and location of all load bearing walls,
beams, and columns. Floor and roof opening
dimensions. Framing and connection details.
Details of projections and appurtenances.
Special inspection requirements.
- DETAILS:
Sections of each exterior an interior
wall and partition type. Section through
each stair type showing rise, run, headroom,
material of construction, and handrail
details. Section through each ramp showing
slope, materials of construction, handrail
height and size. Construction details
showing material type, attachment requirements,
flashing, and installation details. Guardrail
and handrail details indicating height,
size, spacing, extensions, and materials
of construction. Structure details indicating
specific assembly requirements not illustrated
on other drawings.
- STRUCTURAL
CALCULATIONS: Certified calculations
indicating the analytical method used
to determine building structural design.
- SCHEDULES:
Door schedule indicating each door size,
type, and rating. Window schedule indicating
each window type, size, and rating. Finish
schedule indicating finish material and
flame spread rating on walls, floor, and
ceiling in each space. Hardware schedule
indicating locking, latching, gasket material,
and closing mechanism.
- FIRE
ASSEMBLY DETAILS AND REFERENCES: Details
of construction of each fire-resistive
roof/ceiling, floor/ceiling, corridor,
shaft, partition, exterior load-bearing
and non-load-bearing wall, flashing, and
interior load bearing walls. Test assembly
reference number and listing agency for
each assembly. Fire stopping details,
references, and F and T ratings.
- SPECIFICATIONS:
Descriptions, product information, model
numbers, and material specifications.
- HAZARDOUS
MATERIAL LISING: Material Safety Data
Sheets, quantities of use, and storage.
Container size, location of use, and storage.
Name and qualifications of person analyzing
material.
- ELECTRICAL
PLANS: Location of all lights, switches,
panel boxes, receptacles, exit lights,
and emergency lights. Panel board ratings.
Transformer locations and rating.
- MECHANICAL
PLANS: Input rating of all equipment.
Location, size and type of all supply,
return, exhaust, and product conveying
systems. Volume of fresh and circulated
air in each space. Capacity of exhaust
systems.
- PLUMBING
PLANS: Location of all fixtures. Schematic
of system. Location, type, and size of
all supply, waste, and vent systems. Details,
type, and location of drainage system.
- HANDICAPPED
ACCESS: Site access, parking stall
dimensions, stall identification, aisles,
and building access route and grade. Interior
access to all required spaces. Details
showing rest room fixtures and accessories.
Stair and ramp details. Elevator plans.
Seating layout. Signage description.
- FIRE
ALARM PLANS: Panel location. Detection
device type, spacing and location. Supervision
agency and location. Notification device
type and location. Annunciation and communications
system details and operating descriptions.
- SPRINKLER
PLANS: Piping size and type. Head
location, type, and release temperature.
Flow calculations. Specifications.
- ENERGY
REVIEW: Calculations indicating compliance
with applicable Energy Code. (Model Energy
Code, ASHRAE 90.1)
- CERTIFICATIONS:
Architectural, structural, mechanical,
and landscape certifications as required
by state law.
- PLAN
OF EXISTING STRUCTURE: Indicate total
area of building, use of all areas, and
locations of all interior partitions,
stairs, exits, fire assembly ratings,
corridors, and exterior openings. Details
or descriptions of construction assemblies
allowing determination of fire resistive
rating and construction type.
- SHOP
DRAWINGS: Construction documents of
shop-fabricated components. Structural
calculations where appropriate.
- CODE
ANALYSIS: Chapter and section analysis
of all applicable code sections. Includes
occupancy classifications, area analysis,
construction assembly analysis, exiting
analysis, and fire resistive analysis.
Code Plan.
|
|
|
|

City of Des Moines, Iowa
602 Robert D.Ray Drive
Des Moines, Iowa 50309-1881
Phone: (515) 283-4200
E-Mail: actionctr@dmgov.org
Web Site: www.dmgov.org
|
 |